Independent technical knowledge for fluid diagnosticsLaboratory support by Chem-Tech Laboratories
Technical pillar

Grease Analysis

Base oil, thickener, consistency, contamination and wear-debris assessment.

Reviewed Jul 2026 · Oil Testing Atlas editorial team
Orientation

From a fluid result to an equipment decision.

Base oil, thickener, consistency, contamination and wear-debris assessment. This pillar connects fluids, equipment, tests, abnormal findings and corrective actions.

Interpretation should distinguish specification testing, condition monitoring, troubleshooting and research analysis. The same method may support all four, but the sampling design, decision rule and strength of conclusion are different.

Reviewed Jul 2026 · Oil Testing Atlas editorial team
Diagnostic dimensions

Read the evidence as a connected system.

A result gains meaning when companion evidence predicts the same mechanism and the operating context is comparable.

01

Composition

Base oil, thickener and additives define the starting grease system.

  • FTIR
  • Elemental profile
  • Penetration
02

Condition

Shear, heat and separation alter consistency and lubrication.

  • Oil separation
  • Oxidation
  • Hardening
03

Machine evidence

Debris in a representative grease sample can reveal bearing distress.

  • Ferrous debris
  • Morphology
  • Contaminants
Knowledge map

What to examine.

Use topics as investigation branches rather than isolated checkboxes.

01Consistency

Review the relevant fluid, equipment, test and abnormal-pattern evidence before selecting action.

02Thickener

Review the relevant fluid, equipment, test and abnormal-pattern evidence before selecting action.

03Base oil

Review the relevant fluid, equipment, test and abnormal-pattern evidence before selecting action.

04Wear debris

Review the relevant fluid, equipment, test and abnormal-pattern evidence before selecting action.

05Compatibility

Review the relevant fluid, equipment, test and abnormal-pattern evidence before selecting action.

Sampling and data quality

A representative sample is part of the measurement.

Poor sampling can make precise analysis misleading. Fix the location, operating state, flushing practice and supporting records before comparing trends.

Open sampling guide
Grease Analysis sampling controls
ControlRecommended practiceRisk if uncontrolled
Control 1Collect from a representative purge zoneBias, contamination or a non-comparable trend
Control 2Avoid clean fresh grease as the only sampleBias, contamination or a non-comparable trend
Control 3Document regreasing quantity and productBias, contamination or a non-comparable trend
Interpretation framework

Context before alarm.

Grease Analysis interpretation framework
QuestionEvidence requiredWhy it changes the conclusion
Is the sample comparable?Location, interval, operating state and containerSampling variation can mimic a condition change
Did the fluid system change?Grade, make-up, filtration and maintenanceDilution and discontinuities alter concentration
Is the signal corroborated?Companion tests, inspection, filters and machine dataIndependent agreement increases confidence
Which rule governs action?OEM, product specification, contract and jurisdictionUniversal limits are rarely defensible
Related tests

Build a panel around the decision.

Browse all tests →
test

Kinematic Viscosity

Confirm grade and detect dilution, oxidation, shear or contamination. Learn the method principle, sample controls, interpretation limits and related diagnostic evidence.

  • tests
  • physical properties
Open reference
test

Viscosity Index

Describe the temperature sensitivity of lubricant viscosity. Learn the method principle, sample controls, interpretation limits and related diagnostic evidence.

  • tests
  • physical properties
Open reference
test

Elemental Analysis by ICP-OES

Screen wear metals, contaminants and additive elements. Learn the method principle, sample controls, interpretation limits and related diagnostic evidence.

  • tests
  • wear and elemental analysis
Open reference
test

PQ Index

Detect the relative amount of ferromagnetic debris, including particles too large for ICP response. Learn the method principle, sample controls, interpretation limits and related diagnostic evidence.

  • tests
  • wear and elemental analysis
Open reference
test

Analytical Ferrography

Examine wear-particle morphology when routine trends suggest abnormal distress. Learn the method principle, sample controls, interpretation limits and related diagnostic evidence.

  • tests
  • wear and elemental analysis
Open reference
test

Particle Count

Quantify fluid cleanliness and support contamination-control decisions. Learn the method principle, sample controls, interpretation limits and related diagnostic evidence.

  • tests
  • contamination
Open reference
test

Karl Fischer Water

Quantify dissolved, emulsified and finely dispersed water. Learn the method principle, sample controls, interpretation limits and related diagnostic evidence.

  • tests
  • contamination
Open reference
test

Acid Number

Trend acidic constituents associated with oxidation, contamination or additive chemistry. Learn the method principle, sample controls, interpretation limits and related diagnostic evidence.

  • tests
  • chemical condition
Open reference
Technical disclaimer